i2b2 Release 1.7.08a Release Notes
Release Date: November 23, 2016
1.7.08a Release Summary
Release 1.7.08a is primarily focused on fixing and improving the queueing process. The main issue addressed in this release is a fix for an issue that was introduced in 1.7.08; An error was returned when a query timed out and moved on to the medium queue. Although the query continued to run it was misleading to users as they were informed it generated an error an was therefore no longer running. A number of other issues were uncovered during the development and testing of this release. A complete list of each issue can be found in the section titled Change Summary - i2b2 Core Software
Installation Notes
This release note applies to you if you are upgrading to 1.7.08a from an earlier version of i2b2.
If you are installing 1.7.08a from a computer running the i2b2 Workbench, ensure that the workbench and all eclipse applications are closed prior to installing this release.
If you are installing a new instance of i2b2 we recommend you refer to the installation documentation found on the i2b2 community wiki. This documentation will guide you through the entire installation process.
Upgrade Notes
i2b2 Release 1.7.08a contains changes to the following software components:
i2b2 Server
Important The changes to the queueing process were thoroughly tested against an Oracle and SQL Server database. Minimal testing was done against a PostgreSQL database. |
i2b2 Web Client
Note The Web Client contains only one minor fix to the wording of an error message. Upgrading to the new Web Client is not essential for this release. Please see the Change Summary - i2b2 Web Client Software section to see what was changed. |
Change Summary - i2b2 Core Software - Release 1.7.08a
Improvements
[CORE-241] - Queries will immediately move to the next queue when timeout is < or = to 0
Bug Fixes
[CORE-236] - Error returned when query times out
[CORE-242] - Queries are stuck in queue when previous query results in an error
[CORE-243] - Queries do not stop running when they time out of the large queue
[CORE-244] - Statuses are not updated when query times out or an error occurs
Change Summary - i2b2 Web Client Software - Release 1.7.08a
Bug Fixes
[WEBCLIENT-205] - Update date constraint warning message (patient_dimension)
Licensing
The i2b2 source code is licensed under the i2b2 Software License 2.1. This includes but is not limited to all code in the edu.harvard.i2b2.* package namespace.
Trademarks
Microsoft, Windows, Windows 7, Windows Server 2003 and 2008 are either registered trademarks or trademarks of Microsoft Corporation in the United States and / or other countries.
Mac OS is a registered trademark of Apple Inc.
Eclipse Galileo is a registered trademark of the Eclipse Foundation, Inc.